An automatic fire alarm systemtypically made up of. The nfs640, like all notifier intelligent panels, has the exclusive feature of program creation and editing capability from the front panel keypad, while continuing to provide fire protection. In standalone or network configurations, onyx series products meet virtually every application requirement. As a standalone smalltolarge system, or as a large network. The nfs2640 is engineered for midsize applications, designed to maximize flexibility and customization that meet your specific life safety needs.
Nfs2640e intelligent addressable fire alarm system. Fsp851 photo detector fsp851t photo detector w fixed thermal element. The nfs2640s modular design makes system planning easier. The mps24a can also be used to power additional system equipment such as the nca, amg and acs series devices. A1 8292002 fire alarm system limitations while a fire alarm system may lower insurance rates, it is not a substitute for fire insurance. Nfs2640e operating instructions nicholsfiresecurity. Notifier nfs640 smoke alarm installation manual pdf view. Designed with modularity and ease of system planning, the nfs320 can be configured with just a few devices for small. Overview the nfs2640 intelligent fire alarm control panel is part of notifiers ul listed onyx series. Onyx intelligent sensing nine levels of sensitivity, drive compensation and maintenance alert, and auto detector test fully field programmable with 80. General the nfs 640 intelligent fire alarm control panel is part of the onyx series of fire alarm controls from notifier.
The nfs2 640 s modular design makes system planning easier. Its designed specifically for midsize applications, and easily expanded via notifier s intelligent fire alarm network. An automatic fire alarm systemtypically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control with remote notifica. The nfs2 640 intelligent fire alarm control panel is part of notifier s ul listed onyx series. F1 06162011 fire alarm system limitations while a fire alarm system may lower insurance rates, it is not a substitute for fire insurance. Universal electronic alarm systems premier alarm and security specialist. View and download notifier nfs640 installation manual online. B 10032003 3 installation precautions adherence to the following will aid in problemfree installation with longterm reliability. Nfs28 eight zone 002490189 nfs eight zone conventional fire alarm panel, complete with fire and fault relay module and capacitor end of line eol for detector removal monitoring. A a30 nfs 640 shown in cabb4 with nca 640 character display. Notifier nfs640 fire alarm control panel replacement.
P2 71014 3 installation precautions adherence to the following will aid in problemfree installation with longterm reliability. I basically walk the customer through the main functions of the system along. B2 07272004 3 installation precautions adherence to the following will aid in problemfree installation with longterm reliability. Afp1010am2020, nfs640, nfs3030 control panels nac power. An automatic fire alarm systemtypically made up of smoke detectors, heat detectors, manual pull stations, audible. Fieldserver protocol driver sheet notifier onyx nfs640. Notifier nfs2640e universal electronic alarm systems. This is a simple training demonstration of the notifier nfs23030 with dvc. Notifier nfs640 fire alarm control panel replacement board. The nfs2640 is ideal in midsize applications and is easily expandable to meet the requirements of future building expansions. The nfs2640 is engineered specifically for midsize applications, and easily expanded via notifiers intelligent fire alarm network, notifirenet, to accommodate future building expansion. E1 06162011 fire alarm system limitations while a fire alarm system may lower insurance rates, it is not a substitute for fire insurance. Nfs2 640e intelligent addressable fire alarm system intelligent fire alarm control panels dn7111.
A a30 nfs640 shown in cabb4 with nca 640character display. File type pdf notifier nfs2 640 programming manual notifier nfs2 640 programming manual systems in action s1. Download installation manual of notifier nfs640 fire alarms, smoke alarm for free or view it online on. Adapts to your needs the nfs2640s modular design maximizes flexibility and allows customization to your specific fire protection needs. Nfs640 intelligent addressable fire alarm system intelligent fire alarm control panels dn6856. Notifier onyx1nfs640, nfs2640, nfs320 description the nfs640 serial driver allows the fieldserver to record data from notifier. Onyx intelligent sensing nine levels of sensitivity, drive compensation and maintenance alert, and auto.
A ecn 06165 12282006 section 1 operating information normal standby operation. Notifier cpu640 is the replacement board for a notifier onyx nfs640 intelligent addressable fire alarm control panel. Configurations nfs320 nfs2640 nfs2640 fire alarm control panel data sheet. The architecture of the nfs640 software is such that each point entry carries its own program, including controlbyevent links to other points. Notifier fire alarm nfs2640 intelligent fire alarm. Fs870090 notifier onyx nfs640, nfs2640, nfs320 page 3 of 24 fieldserver technologies 1991 tarob court milpitas, california 95035 usa web. Notifier nfs640 cpu640 fire alarm control panel board. B1 12012003 3 installation precautions adherence to the following will aid in problemfree installation with longterm reliability. Notifier cpu640 replacement board for an nfs640 facp. The nfs2640 is ideal for midsize applications, and easily expanded via notifiers intelligent fire alarm network, notifire net, to accommodate future building expansion. View and download notifier nfs640 programming manual online. The notifier kdmr2 keypad for an nfs320 and nfs2640 allows program creation and editing capability from the front panel without interrupting fire protection.
View and download notifier nfs 640 programming manual online. A sierra monitor company chipkin automation systems. Filtered uses aps6r, fcps24 xp6ma six zone interface module use with the nfs640, nfs3030 control panels normal operating voltage. Can poll 318 devices in less than two seconds and activate up to 159 outputs in less than five seconds. Its designed specifically for midsize applications, and easily expanded via notifiers intelligent fire alarm network.
641 1335 1443 1442 853 889 434 185 70 236 1566 690 168 148 1127 764 1020 1618 1231 141 354 1029 252 1642 177 921 58 148 297 84 1541 634 891 1627 637 1479 1645 1429 1366 776 1027 1151 605 309 1157 704 645 273